hotplugd(1M)							  hotplugd(1M)

NAME
       hotplugd - PCI I/O hotplug (attention button) events daemon

SYNOPSIS
       logfile openmode

DESCRIPTION
       The daemon handles PCI I/O hotplug (also known as attention button, AB,
       or doorbell) events that are generated by pressing the attention button
       corresponding to a PCI I/O slot.

       Only one attention button event is processed by the system at any point
       in time.	 If more than one attention button is pressed, the events  are
       put in a queue within the kernel.

       This  daemon invokes to perform the various online addition or replace‐
       ment operations (OLAR, OL*) on the slot on which the  attention	button
       has  been  pressed.  The daemon does not use the (override CRA results)
       option of

       Normally, this daemon is started by the startup script  at  boot	 time.
       See the subsection for details.

       If an attention button is pressed before the startup of the daemon, the
       event is dropped and no messages are logged.  Also see the section  for
       messages that are logged in the system log file or the log file.

       Only  users  with  superuser privileges may use this command to perform
       OL* functions.

       Currently, only the online addition and replacement functions are  sup‐
       ported.	Online deletion is not supported.

       The  blinking  of  the power LED is not supported on all hardware plat‐
       forms.

   Operands
       The following operands are required.  See also the subsection.

       logfile	      Log file where the daemon will log  its  messages.   The
		      standard	output	and  standard error of the command are
		      also captured in this log file.

       openmode	      Mode in which to open the logfile.  It can be one of the
		      following:

		      Open the file in append mode.
				New  log information is appended at the end of
				logfile.

		      Open the file and truncate it.
				If the logfile exists, its length is truncated
				to 0 and the mode and owner are unchanged.

   Daemon Startup
       In  the	normal	(and  recommended)  operation  is invoked at boot time
       through the startup script, The startup script reads the	 configuration
       file,  for  the configuration file variables, and which are assigned to
       the logfile  and	 openmode  parameters,	respectively.	The  installed
       default values are:

       To  start  a  new instance of with new values for logfile and mode, you
       can do so by stopping the running instance of and manually starting  it
       with the new values.

       To  have always invoked on startup with the new values, change the val‐
       ues of the and variables in the configuration file, At the  next	 boot,
       will be invoked with these new values.

DIAGNOSTICS
   Messages in the System Log File
       The  following messages are logged in the system log file, If an atten‐
       tion button event occurs after the daemon has been terminated following
       a successful start of the daemon, the messages are logged in the system
       log file.

	      A chunk of memory, used for storing the attention	 button	 event
	      information, could not be allocated.

	      The  event  is dropped after the power LED is set to mode.  That
	      is, the power LED will be set to ON if the power to the slot  is
	      ON, or the power LED will be set to OFF if the power to the slot
	      is OFF.

	      The queue has not been initialized (daemon not running)  or  the
	      queue is under flow control.  The queue can go into flow control
	      if the queue already has maximum number  of  events.   Currently
	      the maximum is 128.

	      The  event  is  dropped after setting the power LED to mode (see
	      previous message).  Wait till the attention  button  events  are
	      processed by the daemon.

	      The  attention  button  event was received on a slot ID that has
	      not been registered (during the system bootup) with  the	kernel
	      OLAR module.

	      The  event  is  dropped after setting the power LED to mode (see
	      previous message).  Contact your HP response center.

	      The call to get the slot information failed.   olarErrMsg	 gives
	      the reason for the error.

	      This results in an invalid PCI OL* event to the daemon.

	      The  system is clearing the attention button events in the queue
	      due to the abnormal termination of the daemon (for example, with
	      the  signal (see kill(1)) and there are pending attention button
	      events in the queue.

	      While clearing the events from the queue, the  system  sets  the
	      power  LED  corresponding	 to  the slotId, to mode (see previous
	      message).

	      Setting the power LED to mode failed.  The system sets the power
	      LED  to  mode  while  clearing  attention button events from the
	      queue, triggered by the abnormal	termination  of	 the  hotplugd
	      daemon (for example, with the signal (see kill(1)).

   Messages in the hotplugd Daemon Log File
       The  following  messages	 are logged in the daemon log file, defined by
       logfile.

	      An error has occurred on the call to get attention button events
	      from  the	 kernel	 in the mode.  errMsg gives the reason for the
	      error.

	      An error has occurred on the call to get attention button events
	      from  the	 kernel	 in the mode.  errMsg gives the reason for the
	      error.

	      An error has occurred on the call to get attention button events
	      from  the	 kernel	 in the mode.  errMsg gives the reason for the
	      error.  This error occurred within  1  second  of	 the  previous
	      error.   The  daemon  will  sleep	 for  n	 seconds before making
	      another call.

	      The specified oprn PCI OL* operation failed.  oprn may be one of
	      the following:

	      Could  not open the device in the read-write mode.  errMsg gives
	      the reason for the error.

	      Setting the close-on-exec flag on using  failed.	 errMsg	 gives
	      the reason for the error.	 At times, terminating the daemon with
	      may not clear all kernel data structures.	 If you try to restart
	      the  daemon,  it may report an error, In such circumstances, the
	      system must be rebooted to start the daemon successfully.

	      The  initialization  of  for  getting  attention	button	events
	      failed.  olarErrMsg gives the reason for the error.

	      The  initialization  of  for  getting  attention	button	events
	      failed.  errMsg gives the reason for the error.

	      The shutdown of failed.  olarErrMsg gives	 the  reason  for  the
	      error.

	      The shutdown of failed.  errMsg gives the reason for the error.

	      is dropping oprn PCI OL* operation on the slotId slot because it
	      is shutting down.	 time gives the time at	 which	the  attention
	      button was pressed.

	      has  received an invalid PCI OL* operation on slot slotId.  oprn
	      can be one of the following: time	 is  the  time	at  which  the
	      attention button was pressed.

	      This  could  happen if or is received and the slot is not in the
	      right state.  For example, if is received, and the slot  is  not
	      suspended, and the driver is attached, then it is an invalid PCI
	      OL* operation.  Or, it is invalid if is received, and  the  slot
	      is suspended.

	      This could also happen if the call to get the slot status infor‐
	      mation fails.

	      received a PCI OL* operation which it  does  not	understand  on
	      slot  slotId.  oprnCode is the integer representation of the PCI
	      OL* operation.  time is the time at which the  attention	button
	      was pressed.

	      Contact your HP response center.

	      The  attention  button  event  has  been	dropped because it was
	      received while another event was being processed or pending  for
	      the  same	 slotId.   olarIoEvent is the event that was received.
	      It can be one of the following: time gives the time at which the
	      event was received.

	      Wait  for	 the attention button processing on a slot to complete
	      before pressing the attention button again on that slot.

	      The power LED could not be set to mode  for  the	given  slotId.
	      errMsg gives the reason for the error.

	      The  power  LED  could  not be set to mode for the given slotId.
	      olarErrMsg gives the reason for the error.

	      The program was invoked with an invalid set of parameters.

	      could not fork itself.  errMsg gives the reason for the error.

	      could not open the given logFile in write	 mode.	 errMsg	 gives
	      the reason for the error.

	      could  not get the lock on the logFile.  errMsg gives the reason
	      for the error.

	      It could be because another instance of is running.

FILES
       Configuration file for PCI I/O OLAR operations.

       Startup script, used at boot time to start the daemon.

       Installed default name of file where the daemon logs messages.
		      See the section and the subsection for details.

       System log file.
		      See the section for details.

SEE ALSO
       olrad(1M), pdweb(1M), syslogd(1M), errno(2), fcntl(2), ioctl(2)

								  hotplugd(1M)
[top]

List of man pages available for HP-UX

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net