OPTIUPS(8)			  NUT Manual			    OPTIUPS(8)

NAME
       optiups - Driver for Opti-UPS (Viewsonic) UPS and Zinto D (ONLINE-USV)
       equipment

NOTE
       This man page only documents the hardware-specific features of the
       optiups driver. For information about the core driver, see
       nutupsdrv(8).

SUPPORTED HARDWARE
       optiups was originally written against a PowerES 280es in nut-0.45. It
       was revised for nut-2.0.1 and tested against a PowerES 420E. It is
       expected to work with at least the PowerES, PowerPS, and PowerVS
       models.

       This driver additionally supports a Zinto D from ONLINE USV-Systeme AG
       because of their very similar commands, but it is unknown if it also
       works with other UPS from them.

       This driver will not work with the PowerES stock serial cable. You will
       need to construct your own three conductor cable:

	   UPS 6 -> PC 3
	   UPS 9 -> PC 2
	   UPS 4 -> PC 5

       The cable for Online-USV uses pin UPS 7 (not UPS 4) → PC 5.

EXTRA ARGUMENTS
       This driver supports the following optional settings in the ups.conf(5)
       file:

       status_only
	   Only poll for critical status information. Without this, optiups
	   (and all NUT drivers) poll all sorts of information from the UPS
	   fairly often. It is probably not often enough to hurt anything, so
	   this option probably is not very useful, unless you have a flaky
	   serial connection or a highly loaded machine.

       nowarn_noimp
	   Does not print warnings when the UPS reports that a variable is not
	   implemented or not pollable. Without the option you will get a
	   message sent to your system logs each time NUT polls the UPS. If
	   you specify nowarn_noimp, this message will only be logged once.

       fake_lowbatt
	   This forces the low battery flag true. Without it, if you want to
	   test your UPS, you will have to unplug it and wait until the
	   battery drops to a low/critical voltage level before NUT will
	   respond and power down your system. With the flag, NUT should power
	   down the system soon after you pull the plug. When you are done
	   testing, you should remove this flag.

	   For basic shutdown configuration testing, the command upsmon -c fsd
	   is preferred.

       powerup
	   Zinto D from ONLINE-USV cannot be identified when switched to
	   standby. Set this flag to allow the driver to power-up your Zinto
	   UPS. This will also power-up your equipment connected to the UPS!

BUGS
       On the 420E, ups.serial and ups.temperature are unsupported features.
       This is not a bug in NUT or the NUT driver, just the way things are
       with this UPS.

AUTHOR
       Russell Kroll, Scott Heavner, Matthias Goebl

SEE ALSO
   The core driver:
       nutupsdrv(8)

   Internet resources:
       The NUT (Network UPS Tools) home page: http://www.networkupstools.org/

Network UPS Tools		  09/15/2011			    OPTIUPS(8)
[top]

List of man pages available for SuSE

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net