xsetwacom man page on Knoppix

Man page or keyword search:  
man Server   3132 pages
apropos Keyword Search (all sections)
Output format
Knoppix logo
[printable version]

xsetwacom(1)							  xsetwacom(1)

NAME
       xsetwacom  -  commandline utility to query and modify wacom driver set‐
       tings.

SYNOPSIS
       xsetwacom [options] [command [arguments]]

DESCRIPTION
       This program queries or changes properties on the devices loaded by the
       wacom  driver. The modification of properties happens at runtime and is
       not persistent through X server restarts.

GENERAL OPTIONS
       -d, --display display_name
	      Connect to the X server specified in display_name; see X(7).

       -h, --help
	      Prints a short help.

       -v, --verbose
	      Enable verbose output, useful for debugging.

       -V, --version
	      Display version number and exit.

COMMANDS
       Allowed commands are list, get, and set.	 The command may be  specified
       with or without one or two preceding dashes, i.e.  --list is equivalent
       to -list and list.

   LIST COMMANDS
       list devices
	      List known devices. Only input  devices  managed	by  the	 wacom
	      driver are listed.

       list parameters
	      List  known parameters. List all parameters suitable for the get
	      or the set command. Note that not all parameters	are  available
	      on all device types.

       list modifiers
	      List the available list of modifiers to be used when setting key
	      or button actions.

   GET COMMANDS
       get device_name parameter
	      Get the current settings for the parameter on the given  device.
	      Note  that not all parameters are available on all device types.
	      The special parameter name "all" may be provided to display  all
	      current settings on the device.

       By  default,  options  are printed on the commandline in the respective
       format.
	      The output format may be	altered	 with  one  of	the  following
	      options:

       -s, --shell
	      Display  the  output  in shell format, i.e. as shell commands to
	      xsetwacom to reproduce the same parameter.

       -x, --xconf
	      Display the output in xorg.conf format,  i.e.  as	 option	 lines
	      that may be added to the InputDevice section in the xorg.conf.

   SET COMMANDS
       set device_name parameter [value]
	      Set  the	parameter  value on the given device to the value pro‐
	      vided. Note that not all parameters are writable, some are read-
	      only and result in an error when trying to be modified.

PARAMETERS
       Not  all	 parameters  are  available on all tools.  Use the get command
       with the parameter or "all" parameter for specific input tool  applica‐
       ble parameters and current settings.

       Area x1 y1 x2 y2
	      Set  the tablet input area in device coordinates in the form top
	      left x/y and bottom right x/y. Top left  and  bottom  right  are
	      defined  in  the	device's native orientation, regardless of the
	      actual rotation currently applied. Input outside of these	 coor‐
	      dinates  will  be	 clipped  to  the  edges  of the area defined.
	      Default:	0 0 x2 y2; with x2 and y2 tablet specific.

       Button button-number [mapping]
	      Set a mapping for the specified button-number. Mappings take the
	      form of either a single numeric button or an 'action' to be per‐
	      formed. If no  mapping  is  provided,  the  default  mapping  is
	      restored.

	      Numeric  button  mappings	 indicate  what	 X11 button number the
	      given button-number should correspond to. For example, a mapping
	      of  "3" means a press of the given button-number will produce as
	      a press of X11 button 3 (i.e. right click).

	      Action mappings allow button presses  to	perform	 many  events.
	      They  take  the  form of a string of keywords and arguments. For
	      example, "key +a +shift b -shift -a" converts the button into  a
	      series  of  keystrokes,  in  this example "press a, press shift,
	      press and release b, release shift, release a". In  addition  to
	      the  "key"  keyword,  "button"  and "modetoggle" are also recog‐
	      nized. Multiple  keywords	 may  be  present  in  one  action  if
	      desired: for example "key +ctrl button 5 key -ctrl".

       BindToSerial [serial|0]
	      Bind  the	 device	 to the tool with the specified serial number.
	      Once bound, the device will ignore events from  other  tools.  A
	      serial  of  0  means the device is unbound and will react to any
	      tool of the matching type.  Default: 0

       MapToOutput [output]
	      Map the tablet's input area to a	given  output  (e.g.  "VGA1").
	      Output  names may either be the name of a head available through
	      the XRandR extension, or an X11  geometry	 string	 of  the  form
	      WIDTHxHEIGHT+X+Y.	 To  switch  to the next available output, the
	      "next" keyword is also supported. This will  cycle  between  the
	      individual monitors connected to the system, and then the entire
	      desktop. The mapping may be reset to the entire desktop  at  any
	      time  with the output name "desktop". Users of the NVIDIA binary
	      driver should use the output names "HEAD-0" and  "HEAD-1"	 until
	      the driver supports XRandR 1.2 or later.

	      The  output  mapping configuration is a onetime setting and does
	      not track output reconfigurations; the command needs to  be  re-
	      run  whenever  the  output configuration changes. When used with
	      tablet rotation, the tablet must be rotated before it is	mapped
	      to  the  new  screen. This parameter is write-only and cannot be
	      queried.

       Mode Absolute|Relative
	      Set the device mode as either  Relative  or  Absolute.  Relative
	      means  pointer  tracking	for  the  device  will function like a
	      mouse, whereas Absolute means the	 pointer  corresponds  to  the
	      device's	actual	position  on  the  tablet or tablet PC screen.
	      Default:	Absolute for stylus, eraser and tablet PC touch; Rela‐
	      tive for cursor and tablet touch.

       PressureCurve x1 y1 x2 y2
	      A	 Bezier	 curve	of  third order, composed of two anchor points
	      (0,0 and 100,100) and two user modifiable	 control  points  that
	      define  the  curve's  shape.   Raise  the curve (x1<y1 x2<y2) to
	      "soften" the feel and  lower  the	 curve	(x1>y1	x2>y2)	for  a
	      "firmer" feel.  Sigmoid shaped curves are permitted (x1>y1 x2<y2
	      or x1<y1 x2>y2).	Default:  0 0 100 100, a linear	 curve;	 range
	      of 0 to 100 for all four values.

       RawSample level
	      Set  the	sample window size (a sliding average sampling window)
	      for incoming input tool raw data points.	Default:  4, range  of
	      1 to 20.

       Rotate none|half|cw|ccw
	      Set the tablet to the given rotation:
		none: the tablet is not rotated and uses its natural rotation
		half: the tablet is rotated by 180 degrees (upside-down)
		cw: the tablet is rotated 90 degrees clockwise
		ccw: the tablet is rotated 90 degrees counter-clockwise

	      Rotation	is  a tablet-wide option: rotation of one tool affects
	      all other tools associated with the same tablet. When the tablet
	      is physically rotated, rotate any tool to the corresponding ori‐
	      entation.	 Default:  none

       Suppress level
	      Set the delta (difference) cutoff level for  further  processing
	      of  incoming input tool coordinate values.  For example a X or Y
	      coordinate event will be sent only if  the  change  between  the
	      current  X  or Y coordinate and the previous one is greater than
	      the Suppress value.  The same applies to pressure level (Z coor‐
	      dinate) and Tilt rotation values.	 With a current absolute wheel
	      (AbsWheel) or Tilt value the delta between it and	 the  previous
	      value  must  be  equal  to or greater than the Suppress value in
	      order to be sent on.  Suppress is a tablet  wide	parameter.   A
	      specified delta level for one input tool is applied to all input
	      tool coordinates.	 To disable suppression	 use  a	 level	of  0.
	      Default:	2, range of 0 to 100.

       TabletDebugLevel level
	      Set  the	debug  level  for this tablet to the given level. This
	      only affects code paths that are shared between several tools on
	      the same physical tablet. A higher level means more fine-grained
	      debug messages, a level of 0 turns debugging off for this	 tool.
	      Requires the driver to be built with debugging enabled. See also
	      ToolDebugLevel.  Default:	 0, range of 0 to 12.

       TabletPCButton on|off
	      If on, the stylus must be in contact with the screen for a  sty‐
	      lus  side button to work.	 If off, stylus buttons will work once
	      the stylus is in proximity of the tablet (regardless of  whether
	      it  is  touching	the screen).  Default:	on for Tablet PCs; off
	      for all other models.

       ToolSerialPrevious
	      Get the serial number of the tool that  was  last	 in  proximity
	      last.  This  serial number is updated whenever the tool goes out
	      of proximity. If the current tool went out  of  proximity	 once,
	      this  serial  number  is	the one of the current tool. This is a
	      read-only parameter.

       CursorProximity distance
	      sets the max distance from tablet to stop reporting movement for
	      cursor  in  relative  mode. Default for Intuos series is 10, for
	      Graphire series (including Volitos) is 42.  Only	available  for
	      the cursor/puck device.

       Threshold level
	      Set  the	minimum	 pressure necessary to generate a Button event
	      for the stylus tip, eraser, or touch.  The  pressure  levels  of
	      all  tablets  are	 normalized to 2048 levels irregardless of the
	      actual hardware supported levels.	 This parameter is independent
	      of  the  PressureCurve  parameter.   Default:  27, range of 0 to
	      2047.

       ToolDebugLevel level
	      Set the debug level for this tool to the given level. This  only
	      affects  code  paths that are specific to a given tool. A higher
	      level means more fine-grained debug messages, a level of 0 turns
	      debugging	 off  for  this	 tool. Requires the driver to be built
	      with debugging enabled. See also TabletDebugLevel.  Default:  0,
	      range of 0 to 12.

AUTHORS
       Peter Hutterer <peter.hutterer@redhat.com>

SEE ALSO
       Xorg(1), wacom(4), xorg.conf(5), X(7)

       More information is available at http://linuxwacom.sourceforge.net

X Version 11		    xf86-input-wacom 0.15.0		  xsetwacom(1)
[top]

List of man pages available for Knoppix

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net