presto(4)							     presto(4)

Name
       presto - the Prestoserve pseudodevice driver

Syntax
       #include <sys/presto.h>
       #include <sys/prestoioctl.h>

       pseudo-device  presto

Description
       The  Prestoserve	 pseudodevice driver caches synchronous writes in non‐
       volatile memory.	 Prestoserve causes synchronous writes to be performed
       at  memory speeds, rather than at disk speeds.  Synchronous writes that
       result in Prestoserve cache hits do not perform	the  earlier  physical
       disk  writes,  because  only  the  last	write is actually performed by
       Prestoserve.  Therefore, 50% to 65% of  all  the	 physical  disk	 write
       operations  are	avoided,  because every sequential NFS write to a file
       also causes the inode and the indirect block to be synchronously	 writ‐
       ten.

       The  driver  is	layered	 on  other disk drivers, and it intercepts the
       other drivers' I/O requests by replacing the entry points of the origi‐
       nal  driver  in	the  bdevsw  and  cdevsw tables. The driver caches the
       intercepted synchronous write requests in the Prestoserve cache's  non‐
       volatile	 memory.   When	 Prestoserve  needs  to perform actual I/O, it
       calls the original driver's entry points to perform the I/O.   A	 modi‐
       fied  form of Least Recently Used (LRU) replacement determines when the
       Prestoserve cache data needs to be written to the intended disks.

       An accelerated disk device (one that has the pseudodevice  driver  lay‐
       ered  on top of its driver), uses the same major and minor devices that
       it used before it was accelerated.

       The Prestoserve nonvolatile memory must be found at boot time in	 order
       for  Prestoserve	 to  perform its write-caching function.  In addition,
       Prestoserve must pass diagnostic tests, and there  must	be  sufficient
       backup  battery	power  to  guarantee a reasonable amount of cache data
       stability (measured in days or weeks) in the event of a power or	 hard‐
       ware failure.  See the appropriate appendix in the Guide to Prestoserve
       for information on specific processors.

       If the Prestoserve nonvolatile memory is not found or if there  is  not
       enough  backup  battery power, then the disks are not accelerated; how‐
       ever they can be opened and used as usual.  In this  case,  the	driver
       simply  passes  all  I/O	 requests  directly through to the appropriate
       device.

   Operation
       When Prestoserve is in the PRUP state, it caches all synchronous	 write
       requests	 for  enabled  file systems and block devices to the driver in
       nonvolatile memory and writes the Prestoserve cache data asynchronously
       to the intended disks.

       When  Prestoserve  is  in  the  PRDOWN  state,  there is no data in the
       Prestoserve cache, no data is put into the Prestoserve cache,  and  all
       disk requests are passed directly to the real disk driver.

       When  Prestoserve  is in the PRERROR state, the data in the Prestoserve
       cache can not be written to the intended disks because of a disk,  sys‐
       tem, or hardware error.

       When the system is shut down normally by using the system call from the
       or command, the Prestoserve cache  data	is  written  to	 the  intended
       disks, and Prestoserve enters the PRDOWN state.	This allows you to fix
       any system or disk error or to upgrade or change	 your  system  without
       losing the data in the Prestoserve cache or corrupting your disks.

       If  your	 system was shut down without following normal shutdown proce‐
       dures, and you reboot the system, any data in the Prestoserve cache  is
       written	to  the	 intended disks, if possible.  If the data is success‐
       fully written to the intended disks (and if the nonvolatile memory  and
       backup  battery	passed	the  diagnostic tests), Prestoserve enters the
       PRDOWN state.  If an  error  occurs,  Prestoserve  enters  the  PRERROR
       state.	Data  can  exist in the Prestoserve cache after you reboot the
       system only in the event of  a  previous	 power	failure,  disk	device
       error,  or kernel crash that resulted from a software or hardware prob‐
       lem.

       If an error from a disk device occurs or if the backup battery power is
       insufficient,  Prestoserve writes the cache data to the intended disks,
       if possible, and enters the PRERROR state.  When Prestoserve is in  the
       PRERROR	state,	 new  data that is written to a block not found in the
       Prestoserve cache is passed directly to the real disk driver.   If  new
       data  is	 written  to  a	 block that is found in the cache, Prestoserve
       replaces the existing block and attempts to write the block to the real
       disk  driver  to	 determine  if the error condition on that block still
       exists.	If the write is successful and if all the   Prestoserve	 cache
       data  can be written to the intended disks, Prestoserve leaves the PRE‐
       RROR state.

       The Prestoserve cache never discards data without being explicitly told
       to  do  so by using a PRRESET ioctl command.  This can be done by using
       the command.  This command should only be used when there  is  a	 fatal
       disk error and when the data is not important.

   ioctl Commands
       The  pseudodevice  driver  does	not intercept ioctl commands;  they go
       directly to the actual disk driver.  The following ioctl	 commands  can
       be  performed  on  the  Prestoserve  control device Some ioctl commands
       affect all of Prestoserve operation, while others only affect a partic‐
       ular accelerated file system.

       PRGETSTATUS
	      The argument to ioctl is a pointer to a presto_status structure,
	      which contains battery status  information,  Prestoserve	state,
	      current  and  maximum  nonvolatile  memory  sizes,  and  various
	      Prestoserve statistics.

       PRSETSTATE
	      The argument to ioctl is a pointer to an int.  The  int  can  be
	      either   PRUP   to  enable  Prestoserve  or  PRDOWN  to  disable
	      Prestoserve.  When a  system  reboots,  Prestoserve  is  in  the
	      PRDOWN  state  and  must be explicitly enabled by an ioctl.  You
	      enable Prestoserve by using the command, which can be placed  in
	      the  file.    When Prestoserve goes from the PRDOWN state to the
	      PRUP state, the Prestoserve  I/O	statistics  are	 reset.	  When
	      Prestoserve  goes	 from  the PRUP state to the PRDOWN state, all
	      the Prestoserve buffers are written to the intended  disks,  and
	      the buffers are invalidated.

       PRSETMEMSZ
	      The  argument  to ioctl is a pointer to an int.  This int is the
	      size in bytes of the Prestoserve nonvolatile memory to be	 used.
	      This size cannot be larger than the maximum size reported in the
	      presto_status structure.

       PRRESET
	      The argument to ioctl is ignored.	 Like  the  PRSETSTATE	ioctl,
	      PRRESET sets the Prestoserve state to PRDOWN, but it also reini‐
	      tializes all of nonvolatile Prestoserve memory.  If  Prestoserve
	      was  in the PRERROR state and some Prestoserve buffers could not
	      be written to the intended disks because of disk I/O errors, the
	      data  in	the  buffers is lost.  This is the only method you can
	      use to force Prestoserve to discard data that cannot be  written
	      to disk, and it can be accomplished by using the command.

       PRFLUSH
	      The  argument  to	 ioctl	is  ignored.   All  the	 data  in  the
	      Prestoserve buffers is written to the intended  disks,  but  the
	      buffers  are not invalidated. This command can be used by a dae‐
	      mon that flushes the cache periodically to minimize the risk  to
	      data in the event of a catastrophic failure.  The cache data can
	      be flushed to the intended disks by using the command.

       PRGETUPRTAB
	      The argument to ioctl is a  pointer  to  a  struct  uprtab.   On
	      input,  the field upt_bmajordev specifies the block device major
	      number of the device whose struct	 uprtab	 should	 be  returned.
	      The  field  upt_bmajordev	 is set to NODEV , which is defined in
	      the header file if the requested device does not exist or if  it
	      is  not  accelerated.   The struct uprtab contains a upt_enabled
	      field that is a bit vector indexed by a minor device number  and
	      that  indicates  whether the minor device number has Prestoserve
	      caching enabled.

       PRNEXTUPRTAB
	      The argument to ioctl is a pointer to  a	struct	uprtab.	  This
	      ioctl  returns the struct uprtab for the accelerated device with
	      the smallest block device major number that is greater than  the
	      bmajordev field of the struct uprtab argument.  This allows each
	      accelerated device's struct uprtab to be retrieved  sequentially
	      by  specifying  the previous device's block device major number.
	      To get the first accelerated device's  struct  uprtab,  set  the
	      upt_bmajordev  field to NODEV .  Use the same struct uprtab that
	      was returned on the previous call for the next call.   When  the
	      upt_bmajordev  field  of	the  argument struct uprtab is greater
	      than or equal to	the  last  accelerated	device's  major	 block
	      device  number,  the  struct  uprtab  that  is  returned has the
	      upt_bmajordev field set to NODEV.

       PRENABLE
	      The argument to ioctl is a pointer to  a	dev_t.	 This  enables
	      Prestoserve  caching  on	the  specified	file  system  or block
	      device.

       PRDISABLE
	      The argument to ioctl is a pointer to a dev_t.   If  all	cached
	      data  for	 the specified file system or block device can be suc‐
	      cessfully written to disk, Prestoserve caching is	 disabled  for
	      this file system or block device.

Diagnostics
       Prestoserve license not registered
       This message is displayed if you attempt to use Prestoserve on a system
       that has not had its license registered. It is necessary to register  a
       valid license in order to use Prestoserve.

       presto: using %d bytes of NVRAM at 0x%x
       This  message  is displayed at boot time and indicates that Prestoserve
       recognized its control information portion of the cache.	 It is a  nor‐
       mal Prestoserve startup message.

       presto: initializing %d bytes of NVRAM at 0x%x
       This  message  is displayed at boot time and indicates that Prestoserve
       did not recognize the cache as being in either a clean  (containing  no
       data)  or a dirty (containing data) state.  The message is usually dis‐
       played when the cache is used for the first time, after the  cache  has
       been  cleared  by  using	 a diagnostic command, or after backup battery
       failure.

       presto: NVRAM tested %s
       This message is displayed at boot time, and it indicates that the cache
       tested  as  either  "read/write ok" or "readonly ok."  The message is a
       normal Prestoserve startup message.

       presto: %s battery %s
       The status for the primary battery or a secondary battery, if  applica‐
       ble,  is	 reported  as either OK , LOW , or DISABLED .  This message is
       displayed at boot time and when there is a change in the state  of  the
       backup battery power level.

       presto: cache contains dirty data
       This message is displayed at boot time if Prestoserve was not shut down
       by using the normal system shutdown procedures.

       presto: %d dirty buffers found
       This message indicates that dirty buffers were found after  the	system
       rebooted.   The data is written to the intended disks as soon as possi‐
       ble, usually when the first I/O	request	 occurs	 for  any  accelerated
       device.

       presto: writing dirty buffers
       This  message indicates that Prestoserve has begun to write the data in
       the dirty buffers to the intended disks.

       presto: dirty buffers written
       This message indicates that the data in the dirty buffers has been suc‐
       cessfully written to the intended disks.

       presto: using software version %d -- version %d last used
       This message is displayed at boot time and indicates that the kernel is
       now being run with a version of the Prestoserve software that  is  dif‐
       ferent from the version used previously.	 Usually, this message is dis‐
       played when you first boot  the	system	after  performing  a  software
       upgrade.

       presto: expected sizes %d, %d -- found %d, %d
       This  message  indicates	 that  the block size and fragment size in the
       Prestoserve control information portion of the cache are different from
       the  information	 that  was expected.  This message should only be dis‐
       played when you first boot  the	system	after  performing  a  software
       upgrade.

       presto: NVRAM increased from %d to %d bytes at 0x%x
       This message indicates that only a portion of the Prestoserve cache was
       being used when the system was shut down, but now Prestoserve is	 using
       the  entire  cache.   The  command,  which  changes  the	 size  of  the
       Prestoserve cache, is described in in the ULTRIX Reference Pages.

       presto: decreased from %d to %d bytes!
       This message indicates that  a  hardware	 or  software  problem	exists
       because	the  size  of the Prestoserve cache at reboot is less than the
       size of the cache when the system shut down.

       presto: dirty buffers found for host id 0x%x,
       which is different from this host's id (0x%x)
       This message is displayed at boot time and indicates  that  Prestoserve
       was  not shut down normally and that the cache contents were previously
       in a different system (for example, either the cache was moved  or  the
       system ID, which is usually the on-board Ethernet hardware address, has
       changed).  Prestoserve allows you to do one of the  following  interac‐
       tively: discard the data, write the data to disk, or halt the machine.

       The Prestoserve cache failed memory self-tests.
       The cache may contain data which has not been written to disk yet.
       When  these messages are displayed, Prestoserve allows you to do one of
       the following interactively:   continue	with  the  boot	 or  halt  the
       machine.

       presto:	error  %d  opening  dev (%d, %d), skipping writing of its buf‐
       fers...
       This message indicates that dirty Prestoserve buffers were found	 after
       the  system  rebooted,  and  the data in the dirty buffers could not be
       written to the specified device because the device failed to open.  You
       should  verify  that  the device is online and that the kernel success‐
       fully found the device at boot time.  Refer to in the ULTRIX  Reference
       Pages for a complete description of the error.

       presto: error %d opening block device (%d, %d)
       This  message  indicates that the specified device failed to open.  You
       should check your disk configuration and make sure that the drive is on
       line.   Refer  to in the ULTRIX Reference Pages for a complete descrip‐
       tion of the error.

       presto: error %d ioctl'ing dev (%d, %d)
       This message indicates that an ioctl failed for the  specified  device.
       Refer  to  in  the ULTRIX Reference Pages for a complete description of
       the error.

       presto: can NOT do direct I/0 for block device (%d, %d)
       presto: using block device (%d, %d) in `bounceio' mode
       These messages indicate that the	 disk  controller  for	the  specified
       device  could  not  directly  address  the  cache  when Prestoserve was
       enabled on the file system or block device.   Refer  to	the  Guide  to
       Prestoserve for information about bounceio state.

       presto: flush dirty buffers
       This  message is displayed when Prestoserve is in the PRERROR state and
       receives a request to write the data in a dirty buffer to the  intended
       disks.

       presto:	Block device %d not present or is not Presto-ized in this ker‐
       nel!
       This message indicates that Prestoserve was not shut down cleanly,  and
       the  system  was previously running a kernel with an accelerated device
       that the current kernel does not accelerate.  You should boot a	kernel
       that accelerates all the devices that were previously accelerated.

       presto: NVRAM probe error
       This  message  is  displayed  at	 system startup if a Prestoserve cache
       read/write error occurred, and it indicates that the cache could not be
       accessed.  It indicates a hardware or software error.

       presto: failed to write and read 0x%x from 0x%x
       This message indicates that the Prestoserve cache failed the read/write
       test at the specified address.

       presto: error on dev (%d, %d)
       This message indicates that an I/O error occurred on the specified disk
       during a Prestoserve write-back operation.

       presto: not enough backup battery power!
       This  message  indicates that there is inadequate backup battery power.
       Prestoserve attempts  to	 write	all  Prestoserve  cache	 data  to  the
       intended disks and then enters the PRERROR state.

       presto: disabling...
       This  message  indicates	 that  Prestoserve  disabled itself because of
       inadequate backup battery power or because a disk error occurred during
       a write to disk.

       presto: back online!
       This  message  indicates	 that a disk error or low backup battery power
       condition has been corrected and that Prestoserve is enabled again.

   Errors
       [EACCESS]   Indicates that Prestoserve is not  registered  for  use  on
		   this system.

       [EPERM]	   Indicates  that a caller whose uid is not root tried to use
		   the PRSETSTATE, PRSETMEMSZ, PRRESET, PRENABLE or  PRDISABLE
		   command.

       [EBUSY]	   Indicates that you tried to use the PRSETSTATE, PRSETMEMSZ,
		   or PRDISABLE command, but a fatal disk error or  a  battery
		   problem exists.

       [ENOMEM]	   Indicates  that the memory size you specified in the PRSET‐
		   STATE  command  exceeds  the	 maximum  size	of  the	 cache
		   reported in the presto_status structure.

       [ENODEV]	   Indicates  that Prestoserve was not successfully started at
		   boot time, or it indicates that you used  the  PRENABLE  or
		   PRDISABLE  command and the device specified by dev_t is not
		   a device initialized for use with Prestoserve or  an	 error
		   occurred in trying to open/ioctl the device.

       [EINVAL]	   Indicates  that  an invalid argument was specified with the
		   PRSETMEMSZ or PRSETSTATE command or that an invalid command
		   was used.

Files
       Generic Prestoserve control device

See Also
       errno(2), ioctl(2), presto(8), dxpresto(8X), prestoctl_svc(8)
       Guide to Prestoserve

								     presto(4)
[top]

List of man pages available for Ultrix

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net