IBDIAGNET(1) IB DIAGNOSTIC PACKAGE IBDIAGNET(1)NAMEibdiagnet - IB diagnostic net
SYNOPSYSibdiagnet [-c <count>] [-v] [-r] [-vlr] [-u] [-o <out-dir>]
[-t <topo-file>] [-s <sys-name>] [-i <dev-index>] [-p <port-num>]
[-wt]
[-pm] [-pc] [-P <<PM>=<Value>>]
[-lw <1x|4x|12x>] [-ls <2.5|5|10>]
[-skip <ibdiag_check/s>] [-load_db <db_file>]
DESCRIPTIONibdiagnet scans the fabric using directed route packets and extracts
all the available information regarding its connectivity and devices.
It then produces the following files in the output directory (which
defined by the -o option (see below)).
FILES
ibdiagnet.log -
A dump of all the application reports generate according to the
provided flags
ibdiagnet.lst -
List of all the nodes, ports and links in the fabric
ibdiagnet.fdbs -
A dump of the unicast forwarding tables of the fabric switches
ibdiagnet.mcfdbs -
A dump of the multicast forwarding tables of the fabric switches
ibdiagnet.masks -
In case of duplicate port/node Guids, these file include the map
between masked Guid and real Guids
ibdiagnet.sm -
List of all the SM (state and priority) in the fabric
ibdiagnet.pm -
A dump of the pm Counters values, of the fabric links
ibdiagnet.pkey -
A dump of the the existing partitions and their member host ports
ibdiagnet.mcgs -
A dump of the multicast groups, their properties and member host
ports
ibdiagnet.psl -
A dump of the path record SL of each possible source node guid and
DLID pairs. Created only if -vlr option is provided
ibdiagnet.slvl -
A dump of the SL2VL Tables from all the switches. Created only if
-vlr option is provided
ibdiagnet.db -
A dump of the internal subnet database. This file can be loaded in
later runs using the -load_db option
In addition to generating the files above, the discovery phase also
checks for duplicate node/port GUIDs in the IB fabric. If such an error
is detected, it is displayed on the standard output. After the
discovery phase is completed, directed route packets are sent multiple
times (according to the -c option) to detect possible problematic paths
on which packets may be lost. Such paths are explored, and a report of
the suspected bad links is displayed on the standard output.
After scanning the fabric, if the -r option is provided, a full report
of the fabric qualities is displayed. This report includes:
· SM report
· Number of nodes and systems
· Hop-count information
maximal hop-count, an example path, and a hop-count histogram
· All CA-to-CA paths traced
· Credit loop report
· mgid-mlid-HCAs multicast group and report
· Partitions report
· IPoIB report
Note: In case the IB fabric includes only one CA, then CA-to-CA paths
are not reported. Furthermore, if a topology file is provided,
ibdiagnet uses the names defined in it for the output reports.
OPTIONS-c <count> :
Min number of packets to be sent across each link (default = 10)
-v :
Enable verbose mode
-r :
Provides a report of the fabric qualities
-u :
Credit loop check based on UpDown rules
-t <topo-file> :
Specifies the topology file name
-s <sys-name> :
Specifies the local system name. Meaningful only if a topology
file is specified
-i <dev-index> :
Specifies the index of the device of the port used to connect to
the IB fabric (in case of multiple devices on the local system)
-p <port-num> :
Specifies the local device's port num used to connect to the IB
fabric
-o <out-dir> :
Specifies the directory where the output files will be placed
(default = /var/cache/ibutils)
-lw <1x|4x|12x> :
Specifies the expected link width
-ls <2.5|5|10> :
Specifies the expected link speed
-pm :
Dump all the fabric links, pm Counters into ibdiagnet.pm
-pc :
Reset all the fabric links pmCounters
-P <PM=<Trash>> :
If any of the provided pm is greater then its provided value,
print it to screen
-skip <skip-option(s)> :
Skip the executions of the selected checks. Skip options (one or
more can be specified) : dup_guids zero_guids pm logical_state
part ipoib all
-wt <file-name>> :
Write out the discovered topology into the given file. This flag
is useful if you later want to check for changes from the current
state of the fabric. A directory named ibdiag_ibnl is also created
by this option, and holds the IBNL files required to load this
topology. To use these files you will need to set the environment
variable named IBDM_IBNL_PATH to that directory. The directory is
located in /var/cache/ibutils or in the output directory provided
by the -o flag.
-load_db <file-name>> :
Load subnet data from the given .db file, and skip subnet
discovery stage. Note: Some of the checks require actual subnet
discovery, and therefore would not run when load_db is specified.
These checks are : Duplicated/zero guids, link state, SMs status.
-vlr :
VL based Routing - provide this option to create the paths SL file
(psl), SL2VL file (slvl) and use them in credit loops check (if -r
option is provided).
NOTE: Since number of paths is N^2 extracting the PSL file may
take some time.
-h|--help :
Prints the help page information
-V|--version :
Prints the version of the tool
--vars :
Prints the tool's environment variables and their values
ERROR CODES
1 - Failed to fully discover the fabric
2 - Failed to parse command line options
3 - Failed to intract with IB fabric
4 - Failed to use local device or local port
5 - Failed to use Topology File
6 - Failed to load requierd Package
IBDIAG 1.0 2013-08-28 IBDIAGNET(1)