PCPINTRO(1)							   PCPINTRO(1)

NAME
       PCPIntro - introduction to the Performance Co-Pilot (PCP)

INTRODUCTION
       The Performance Co-Pilot (PCP) is a toolkit designed for monitoring and
       managing system-level performance.  These services are distributed  and
       scalable to accommodate the most complex system configurations and per‐
       formance problems.

       PCP supports many different platforms, including (but not  limited  to)
       Linux,  MacOSX, Solaris and Windows.  From a high-level PCP can be con‐
       sidered to contain two classes of software utility:

       PCP Collectors
	       These are the parts of PCP that collect and extract performance
	       data from various sources, e.g. the operating system kernel.

       PCP Monitors
	       These  are  the	parts  of PCP that display data collected from
	       hosts (or archives) that	 have  the  PCP	 Collector  installed.
	       Many  monitor  tools  are  available  as	 part  of the core PCP
	       release, while other (typically graphical) monitoring tools are
	       available separately in the PCP GUI package.

       This  manual entry describes the high-level features and options common
       to most PCP utilities available on all platforms.

OVERVIEW
       The PCP architecture is distributed in the sense that any PCP tool  may
       be  executing  remotely.	  On the host (or hosts) being monitored, each
       domain of performance metrics, whether the kernel, a service  layer,  a
       database	 management  system,  a	 web  server,  an  application,	  etc.
       requires a Performance Metrics Domain Agent (PMDA) which is responsible
       for  collecting	performance  measurements from that domain.  All PMDAs
       are controlled by the Performance Metrics Collector Daemon (pmcd(1)) on
       the same host.

       Client  applications  (the  monitoring tools) connect to pmcd(1), which
       acts as a router for requests, by forwarding requests to the  appropri‐
       ate  PMDA and returning the responses to the clients.  Clients may also
       access performance data from a PCP archive (created using  pmlogger(1))
       for retrospective analysis.

   Security philosophy
       PCP redistributes a wealth of performance information within a host and
       across its networks.  The following security philosophy	underlies  the
       setting	of  several defaults that control how much information is sent
       and received.

       By default, the information exposed by PMCD about a  host  is  approxi‐
       mately  of  the	same  level  of confidentiality as available to a com‐
       pletely unprivileged user on that host.	So, performance data  that  is
       available  to be read completely freely on a machine may be made avail‐
       able by PMCD to the network.

       However, the host running PMCD and its network is not  assumed  to  run
       only  friendly applications.  Therefore, write type operations, includ‐
       ing from the local host, are not permitted by default.

       These defaults may be overridden (expanded or reduced) in several ways,
       including  by  specifying  network  ACLs	 in pmcd.conf, activating non-
       default PMDAs, or by using PMCD connections that pass user credentials.
       For  example,  some PMDAs automatically provide greater information for
       particular credentialed users or groups.

   Applications
       The following performance monitoring applications are primarily console
       based,  typically  run  directly	 from the command line, and are just a
       small subset of the tools available as part of the base PCP package.

       Each tool or command is documented  completely  in  its	own  reference
       page.

       pmstat Outputs an ASCII high-level summary of system performance.

       pmie   An  inference engine that can evaluate predicate-action rules to
	      perform alarms and automate system management tasks.

       pminfo Interrogate specific performance metrics and the	metadata  that
	      describes them.

       pmlogger
	      Generates	 PCP  archives	of  performance	 metrics  suitable for
	      replay by most PCP tools.

       pmval  Simple periodic reporting for some or all instances of a perfor‐
	      mance metric, with optional VCR time control.

       If the PCP GUI package is installed then the following additional tools
       are available.

       pmchart
	      Displays trends over time of  arbitrarily	 selected  performance
	      metrics from one or more hosts.

       pmtime Time  control utility for coordinating the time between multiple
	      tools (including pmchart and pmval).

       pmdumptext
	      Produce ASCII reports for arbitrary combinations of  performance
	      metrics.

COMMON COMMAND LINE ARGUMENTS
       There  is  a set of common command line arguments that are used consis‐
       tently by most PCP tools.

       -a archive
	      Performance metric information is retrospectively retrieved from
	      the  Performance Co-Pilot (PCP) archive, previously generated by
	      pmlogger(1).  The -a and -h options are mutually exclusive.

	      archive is either the base name common to all  of	 the  physical
	      files  created  by an instance of pmlogger(1), or any one of the
	      physical files, e.g.  myarchive (base  name)  or	myarchive.meta
	      (the  metadata  file) or myarchive.index (the temporal index) or
	      myarchive.0   (the   first   data	  volume   of	archive)    or
	      myarchive.0.bz2  or  myarchive.0.bz  (the first data volume com‐
	      pressed with bzip2(1)) or	 myarchive.0.gz	 or  myarchive.0.Z  or
	      myarchive.0.z  (the  first data volume compressed with gzip(1)),
	      myarchive.1 or myarchive.3.bz2 or myarchive.42.gz etc.

       -a archive[,archive,...]
	      An alternate form of -a for applications that are able to handle
	      multiple archives.

       -h hostname
	      Unless  directed	to another host by the -h option, or to an ar‐
	      chive by the -a option, the source of performance	 metrics  will
	      be  the Performance Metrics Collector Daemon (PMCD) on the local
	      host.  Refer to the PMCD HOST SPECIFICATION  section  later  for
	      further  details	on the many options available when forming the
	      hostname specification, as well as a detailed description of the
	      default  local host connection.  The -a and -h options are mutu‐
	      ally exclusive.

       -s samples
	      The argument  samples  defines  the  number  of  samples	to  be
	      retrieved and reported.  If samples is 0 or -s is not specified,
	      the application will sample and  report  continuously  (in  real
	      time  mode)  or  until  the  end	of the PCP archive (in archive
	      mode).

       -z     Change the reporting timezone to the local timezone at the  host
	      that is the source of the performance metrics, as identified via
	      either the -h or -a options.

       -Z timezone
	      By default, applications report the time of day according to the
	      local  timezone on the system where the application is executed.
	      The -Z option changes the timezone to timezone in the format  of
	      the environment variable TZ as described in environ(5).

INTERVAL SPECIFICATION AND ALIGNMENT
       Most  PCP tools operate with periodic sampling or reporting, and the -t
       and -A options may be used to control the duration of the sample inter‐
       val and the alignment of the sample times.

       -t interval
	      Set the update or reporting interval.

	      The  interval argument is specified as a sequence of one or more
	      elements of the form
			number[units]
	      where number is an integer or floating  point  constant  (parsed
	      using strtod(3)) and the optional units is one of: seconds, sec‐
	      ond, secs, sec, s, minutes, minute, mins, min, m,	 hours,	 hour,
	      h, days, day and d.  If the unit is empty, second is assumed.

	      In  addition,  the  upper case (or mixed case) version of any of
	      the above is also acceptable.

	      Spaces anywhere in the interval are ignored, so 4 days  6	 hours
	      30  minutes,  4day6hour30min, 4d6h30m and 4d6.5h are all equiva‐
	      lent.

	      Multiple	specifications	are  additive,	e.g.  ``1hour	15mins
	      30secs'' is interpreted as 3600+900+30 seconds.

       -A align
	      By  default  samples  are not necessarily aligned on any natural
	      unit of time.  The -A option may be used to  force  the  initial
	      sample  to  be  aligned  on the boundary of a natural time unit.
	      For example -A 1sec, -A 30min and -A 1hour specify alignment  on
	      whole seconds, half and whole hours respectively.

	      The  align  argument follows the syntax for an interval argument
	      described above for the -t option.

	      Note that alignment occurs by advancing the  time	 as  required,
	      and  that -A acts as a modifier to advance both the start of the
	      time window (see the next section) and the origin time  (if  the
	      -O option is specified).

TIME WINDOW SPECIFICATION
       Many PCP tools are designed to operate in some time window of interest,
       e.g. to define a termination time for real-time monitoring or to define
       a start and end time within a PCP archive log.

       In  the	absence	 of the -O and -A options to specify an initial sample
       time origin and time alignment (see above), the	PCP  application  will
       retrieve the first sample at the start of the time window.

       The following options may be used to specify a time window of interest.

       -S starttime
	      By  default  the	time window commences immediately in real-time
	      mode, or coincides with time at the start of the PCP archive log
	      in  archive  mode.  The -S option may be used to specify a later
	      time for the start of the time window.

	      The starttime parameter may be  given  in	 one  of  three	 forms
	      (interval	 is  the same as for the -t option as described above,
	      ctime is described below):

	      interval
		     To specify an offset from the current time (in  real-time
		     mode) or the beginning of a PCP archive (in archive mode)
		     simply specify the interval of time as the argument.  For
		     example -S 30min will set the start of the time window to
		     be exactly 30 minutes from	 now  in  real-time  mode,  or
		     exactly 30 minutes from the start of a PCP archive.

	      -interval
		     To	 specify  an offset from the end of a PCP archive log,
		     prefix the interval argument with a minus sign.  In  this
		     case,  the	 start of the time window precedes the time at
		     the end of archive by the given interval.	For example -S
		     -1hour  will  set	the  start  of	the  time window to be
		     exactly one hour before the time of the last sample in  a
		     PCP archive log.

	      @ctime To	 specify the calendar date and time (local time in the
		     reporting timezone) for the start of the time window, use
		     the  ctime(3) syntax preceded by an at sign.  For example
		     -S '@ Mon Mar 4 13:07:47 1996'

       -T endtime
	      By default the end of the time window is unbounded (in real-time
	      mode)  or	 aligned with the time at the end of a PCP archive log
	      (in archive mode).  The -T option may be used to specify an ear‐
	      lier time for the end of the time window.

	      The endtime parameter may be given in one of three forms (inter‐
	      val is the same as for the -t option as described	 above,	 ctime
	      is described below):

	      interval
		     To	 specify  an  offset from the start of the time window
		     simply use the interval of time  as  the  argument.   For
		     example  -T  2h30m will set the end of the time window to
		     be 2 hours and 30 minutes after the  start	 of  the  time
		     window.

	      -interval
		     To	 specify  an offset back from the time at the end of a
		     PCP archive log, prefix  the  interval  argument  with  a
		     minus  sign.  For example -T -90m will set the end of the
		     time window to be 90 minutes before the time of the  last
		     sample in a PCP archive log.

	      @ctime To	 specify the calendar date and time (local time in the
		     reporting timezone) for the end of the time  window,  use
		     the  ctime(3) syntax preceded by an at sign.  For example
		     -T '@ Mon Mar 4 13:07:47 1996'

       -O origin
	      By default samples are fetched from the start of the time window
	      (see  description	 of  -S	 option) to the end of the time window
	      (see description of -T option).  The -O option allows the speci‐
	      fication	of  an origin within the time window to be used as the
	      initial sample time.  This is useful for interactive  use	 of  a
	      PCP tool with the pmtime(1) VCR replay facility.

	      The  origin  argument accepted by -O conforms to the same syntax
	      and semantics as the starttime argument for the -T option.

	      For example -O -0 specifies that the initial position should  be
	      at  the end of the time window; this is most useful when wishing
	      to replay ``backwards'' within the time window.

       The ctime argument for the -O, -S and -T options is based upon the cal‐
       endar  date  and	 time format of ctime(3), but may be a fully specified
       time string like Mon Mar	 4 13:07:47 1996 or a partially specified time
       like Mar 4 1996, Mar 4, Mar, 13:07:50 or 13:08.

       For any missing low order fields, the default value of 0 is assumed for
       hours, minutes and seconds, 1 for day of the month and Jan for  months.
       Hence,  the  following  are equivalent: -S '@ Mar 1996' and -S '@ Mar 1
       00:00:00 1996'.

       If any high order fields are missing, they are filled  in  by  starting
       with  the year, month and day from the current time (real-time mode) or
       the time at the beginning of the PCP archive  log  (archive  mode)  and
       advancing the time until it matches the fields that are specified.  So,
       for example if the time	window	starts	by  default  at	 ``Mon	Mar  4
       13:07:47	 1996'',  then -S @13:10 corresponds to 13:10:00 on Mon Mar 4,
       1996, while -S @10:00 corresponds to 10:00:00 on Tue Mar 5, 1996	 (note
       this is the following day).

       For  greater precision than afforded by ctime(3), the seconds component
       may be a floating point number.

       Also the 12 hour clock (am/pm notation) is supported,  so  for  example
       13:07 and 1:07 pm are equivalent.

PERFORMANCE METRICS - NAMES AND IDENTIFIERS
       The  number  of performance metric names supported by PCP on most plat‐
       forms ranges from many hundreds to several thousand.  The PCP libraries
       and  applications  use an internal identification scheme that unambigu‐
       ously associates a single integer with each known  performance  metric.
       This  integer  is  known as the Performance Metric Identifier, or PMID.
       Although not a requirement,  PMIDs  tend	 to  have  global  consistency
       across  all systems, so a particular performance metric usually has the
       same PMID.

       For all users and most applications, direct use of the PMIDs  would  be
       inappropriate  (e.g.  this would limit the range of accessible metrics,
       make the code hard to maintain, force the user interface to be particu‐
       larly baroque, etc.).  Hence a Performance Metrics Name Space (PMNS) is
       used to provide external names and a hierarchic classification for per‐
       formance metrics.  A PMNS is represented as a tree, with each node hav‐
       ing a label, a pointer to either a PMID (for leaf nodes) or  a  set  of
       descendent nodes in the PMNS (for non-leaf nodes).

       A  node label must begin with an alphabetic character, followed by zero
       or more characters drawn from the alphabetics, the digits and character
       `_´ (underscore).  For alphabetic characters in a node label, upper and
       lower case are distinguished.

       By convention, the name of a performance metric is constructed by  con‐
       catenation  of the node labels on a path through the PMNS from the root
       node to a leaf node, with a ``.'' as a separator.  The root node in the
       PMNS  is	 unlabeled,  so all names begin with the label associated with
       one of the descendent nodes below the root node of the PMNS, e.g.  ker‐
       nel.percpu.syscall.   Typically	(although  this	 is not a requirement)
       there would be at most one name for each PMID in a PMNS.	  For  example
       kernel.all.cpu.idle and disk.dev.read are the unique names for two dis‐
       tinct performance metrics, each with a unique PMID.

       Groups of related PMIDs may be named by naming a non-leaf node  in  the
       PMNS tree, e.g. disk.

       The    default	 local	  PMNS	  used	 by   pmcd   is	  located   at
       $PCP_VAR_DIR/pmns/root however the  environment	variable  PMNS_DEFAULT
       may  be set to the full pathname of a different PMNS which will then be
       used as the default local PMNS.

       Most applications do not use the local PMNS directly, but rather import
       parts of the PMNS as required from the same place that performance met‐
       rics are fetched, i.e. from pmcd(1) for live monitoring or from	a  PCP
       archive for retrospective monitoring.

       To  explore  the	 PMNS  use  pminfo(1),	or  if	the PCP GUI package is
       installed the New Chart and Metric Search windows within pmchart(1).

PERFORMANCE METRIC SPECIFICATIONS
       In configuration files and (to a lesser extent) command	line  options,
       metric specifications adhere to the following syntax rules.

       If the source of performance metrics is real-time from pmcd(1) then the
       accepted syntax is
		 host:metric[instance1,instance2,...]

       If the source of performance metrics is a  PCP  archive	log  then  the
       accepted syntax is
		 archive/metric[instance1,instance2,...]

       The  host:,  archive/ and [instance1,instance2,...]  components are all
       optional.

       The , delimiter in the list of instance names may be replaced by	 white
       space.

       Special	characters in instance names may be escaped by surrounding the
       name in double quotes or preceding the character with a backslash.

       White space is ignored everywhere except within a quoted instance name.

       An empty instance is silently ignored, and in particular ``[]'' is  the
       same as no instance, while ``[one,,,two]'' is parsed as specifying just
       the two instances ``one'' and ``two''.

       As a special case, if the host is the single character ``@'' then  this
       refers to a PM_CONTEXT_LOCAL source, see pmNewContext(3).

SECURE PMCD CONNECTIONS
       Since  PCP  version  3.6.11,  a monitor can explicitly request a secure
       connection to a collector host running pmcd(1) or pmproxy(1) using  the
       PM_CTXFLAG_SECURE  context  flag.   If  the PCP Collector host supports
       this feature - refer to the pmcd.feature.secure metric for confirmation
       of  this - a TLS/SSL (Transport Layer Security or Secure Sockets Layer)
       connection can be established which uses public	key  cryptography  and
       related	techniques.   These  features aim to prevent eavesdropping and
       data tampering from a malicious	third  party,  as  well	 as  providing
       server-side  authentication  (confident identification of a server by a
       client) which can be used to guard against man-in-the-middle attacks.

       A secure pmcd connection requires use of certificate-based  authentica‐
       tion.   The  security  features	offered by pmcd and pmproxy are imple‐
       mented using the Network Security Services (NSS)	 APIs  and  utilities.
       The  NSS	 certutil tool can be used to create certificates suitable for
       establishing trust between PCP monitor and collector hosts.

       A complete description is beyond the scope of this document,  refer  to
       the  PCP ENVIRONMENT, FILES and SEE ALSO sections for detailed informa‐
       tion.  This includes links to tutorials on the steps involved  in  set‐
       ting up the available security features.

PMCD HOST SPECIFICATION
       In  the absence of an explicit host name specification, most tools will
       default to the local host in live update mode.  In PCP  releases	 since
       3.8.4  onward,  this  results  in  an  efficient	 local	protocol being
       selected - typically a Unix domain socket.   If	this  option  is  used
       (which  can  also be explicitly requested via the unix: host specifica‐
       tion described below), it is important to  note	that  all  connections
       will be automatically authenticated. In other words, the credentials of
       the user invoking a client tool will automatically be made available to
       pmcd(1)	and  all  of its PMDAs, on the users behalf, such that results
       can be customized to the privilege levels of individual users.

       Names of remote hosts running the pmcd(1) daemon can of course also  be
       provided to request a remote host be used.  The most basic form of pmcd
       host specification is a simple host name, possibly including the domain
       name  if	 necessary.  However, this can be extended in a number of ways
       to further refine attributes of the connection made to pmcd.

       The pmcd port number and also optional pmproxy(1) hostname and its port
       number,	can be given as part of the host specification, since PCP ver‐
       sion 3.0.  These supersede  (and	 override)  the	 old-style  PMCD_PORT,
       PMPROXY_HOST and PMPROXY_PORT environment variables.

       The  following  are  valid hostname specifications that specify connec‐
       tions to pmcd on host nas1.servers.com with/without a list of ports and
       with/without a pmproxy(1) connection through a firewall.

	    $ pcp -h nas1.servers.com:44321,4321@firewall.servers.com:44322
	    $ pcp -h nas1.servers.com:44321@firewall.servers.com:44322
	    $ pcp -h nas1.servers.com:44321@firewall.servers.com
	    $ pcp -h nas1.servers.com@firewall.servers.com
	    $ pcp -h nas1.servers.com:44321

       In addition, security attributes and credentials can also be specified.
       These include username, an optional password  (can  be  given  interac‐
       tively  and  may	 depend	 on  the  authentication  mechanism employed),
       whether to use secure (encrypted) or native (naked)  protocol,  and  so
       on.  The	 previous  examples all default to native protocol, and use no
       authentication.	This can be altered, as in the following examples.

	    $ pcp -h pcps://nas1.servers.com:44321?username=tanya&method=gssapi
	    $ pcp -h pcps://nas2.servers.com@firewalls.r.us?method=plain
	    $ pcp -h pcp://nas3.servers.com
	    $ pcp -h unix:
	    $ pcp -h local:

       The choice of authentication method,  and  other	 resulting  parameters
       like  username, optionally password, etc, depends on the SASL2 configu‐
       ration used by each (remote) pmcd.  Tutorials are available  specifying
       various aspects of configuring the authentication module(s) used, these
       fine details are outside the scope of this document.

       The final local: example above is now the default for most tools.  This
       connection  is  an automatically authenticated local host connection on
       all platforms  that  support  Unix  domain  sockets.   No  password  is
       required	 and authentication is automatic.  This is also the most effi‐
       cient (lowest overhead) communication channel available.

       The difference between unix: and local: is that the former is a	strict
       Unix domain socket specification (connection fails if it cannot connect
       that way), whereas the latter has a more forgiving  fallback  to	 using
       localhost  (i.e.	 a  regular  Inet  socket connection is used when Unix
       domain socket connections are unavailable).

ENVIRONMENT
       In addition to the PCP run-time environment and configuration variables
       described  in the PCP ENVIRONMENT section below, the following environ‐
       ment variables apply to all installations.

       PCP_CONSOLE
	      When set, this changes the default  console  from	 /dev/tty  (on
	      Unix)  or	 CON:  (on  Windows) to be the specified console.  The
	      special value of none can be used	 to  indicate  no  console  is
	      available	 for  use.  This is used in places where console-based
	      tools need to interact with the user, and in particular is  used
	      when authentication is being performed.

       PCP_DERIVED_CONFIG
	      When set, this variable defines the path to a file that contains
	      definitions of derived metrics as per the	 syntax	 described  in
	      pmLoadDerivedConfig(3).	Derived	 metrics may be used to extend
	      the available metrics with new (derived)	metrics	 using	simple
	      arithmetic expressions.

	      If PCP_DERIVED_CONFIG is set, the derived metric definitions are
	      processed automatically as each new source of  performance  met‐
	      rics is established (i.e. each time a pmNewContext(3) is called)
	      or when requests are made against the PMNS.

       PCP_SECURE_SOCKETS
	      When set, this variable forces any monitor tool  connections  to
	      be  established  using the certificate-based secure sockets fea‐
	      ture.  If the connections cannot be established  securely,  they
	      will fail.

       PCP_SECURE_DB_METHOD
	      With secure socket connections, the certificate and key database
	      is   stored   using   the	  sql:	 method	  by   default.	   Use
	      PCP_SECURE_DB_METHOD  to override the default, most usually set‐
	      ting the value to the empty string (for the older database meth‐
	      ods).

       PCP_STDERR
	      Many  PCP	 tools	support	 the  environment variable PCP_STDERR,
	      which can be used to control  where  error  messages  are	 sent.
	      When  unset, the default behavior is that ``usage'' messages and
	      option parsing errors are reported on standard error, other mes‐
	      sages  after initial startup are sent to the default destination
	      for the tool, i.e. standard error for ASCII tools, or  a	dialog
	      for GUI tools.

	      If  PCP_STDERR is set to the literal value DISPLAY then all mes‐
	      sages will be displayed in a dialog.  This is used for any tools
	      launched from the a Desktop environment.

	      If PCP_STDERR is set to any other value, the value is assumed to
	      be a filename, and all messages will be written there.

       PMCD_CONNECT_TIMEOUT
	      When attempting to connect to a remote pmcd(1) on a machine that
	      is booting, the connection attempt could potentially block for a
	      long time until the remote machine finishes its  initialization.
	      Most  PCP applications and some of the PCP library routines will
	      abort and return an error if the connection has not been	estab‐
	      lished  after  some specified interval has elapsed.  The default
	      interval	is  5  seconds.	  This	may  be	 modified  by  setting
	      PMCD_CONNECT_TIMEOUT in the environment to a real number of sec‐
	      onds for the desired timeout.  This  is  most  useful  in	 cases
	      where the remote host is at the end of a slow network, requiring
	      longer latencies to establish the connection correctly.

       PMCD_RECONNECT_TIMEOUT
	      When a monitor or client application loses  a  connection	 to  a
	      pmcd(1),	the connection may be re-established by calling a ser‐
	      vice routine in the PCP library.	However, attempts to reconnect
	      are controlled by a back-off strategy to avoid flooding the net‐
	      work with	 reconnection  requests.   By  default,	 the  back-off
	      delays  are  5, 10, 20, 40 and 80 seconds for consecutive recon‐
	      nection requests from a client (the last delay will be  repeated
	      for any further attempts after the fifth).  Setting the environ‐
	      ment variable PMCD_RECONNECT_TIMEOUT to a comma  separated  list
	      of  positive  integers  will re-define the back-off delays, e.g.
	      setting PMCD_RECONNECT_TIMEOUT to ``1,2'' will  back-off	for  1
	      second,  then attempt another connection request every 2 seconds
	      thereafter.

       PMCD_REQUEST_TIMEOUT
	      For monitor or client applications connected to  pmcd(1),	 there
	      is  a  possibility of the application "hanging" on a request for
	      performance metrics or metadata or help text.  These delays  may
	      become severe if the system running pmcd crashes, or the network
	      connection  is  lost.   By  setting  the	environment   variable
	      PMCD_REQUEST_TIMEOUT  to	a  number of seconds, requests to pmcd
	      will timeout after this number of seconds.  The default behavior
	      is  to  be  willing to wait 10 seconds for a response from every
	      pmcd for all applications.

       PMCD_WAIT_TIMEOUT
	      When pmcd(1) is started from $PCP_RC_DIR/pcp  then  the  primary
	      instance	of  pmlogger(1)	 will  be started if the configuration
	      flag pmlogger is chkconfig'ed on and pmcd is running and accept‐
	      ing connections.

	      The  check on pmcd's readiness will wait up to PMCD_WAIT_TIMEOUT
	      seconds.	If pmcd has a long startup time (such  as  on  a  very
	      large  system),  then  PMCD_WAIT_TIMEOUT can be set to provide a
	      maximum wait longer than the default 60 seconds.

       PMNS_DEFAULT
	      If set, then interpreted as the full pathname to be used as  the
	      default  local  PMNS  for	 pmLoadNameSpace(3).   Otherwise,  the
	      default local PMNS is located at $PCP_VAR_DIR/pcp/pmns/root  for
	      base PCP installations.

       PCP_COUNTER_WRAP
	      Many  of	the  performance metrics exported from PCP agents have
	      the semantics of counter meaning they are expected to  be	 mono‐
	      tonically	 increasing.   Under  some circumstances, one value of
	      these metrics may smaller than  the  previously  fetched	value.
	      This can happen when a counter of finite precision overflows, or
	      when the PCP agent has been reset or restarted, or when the  PCP
	      agent  is	 exporting values from some underlying instrumentation
	      that is subject to some asynchronous discontinuity.

	      The environment variable PCP_COUNTER_WRAP may be set to indicate
	      that  all	 such  cases  of  a  decreasing	 ``counter'' should be
	      treated as a counter overflow, and hence the values are  assumed
	      to  have	wrapped	 once in the interval between consecutive sam‐
	      ples.  This ``wrapping'' behavior was the default in earlier PCP
	      versions,	 but  by default has been disabled in PCP release from
	      version 1.3 on.

       PMDA_PATH
	      The PMDA_PATH environment variable may be	 used  to  modify  the
	      search  path  used  by  pmcd(1) and pmNewContext(3) (for PM_CON‐
	      TEXT_LOCAL contexts) when searching for a daemon	or  DSO	 PMDA.
	      The  syntax  follows  that for PATH in sh(1), i.e. a colon sepa‐
	      rated list of  directories,  and	the  default  search  path  is
	      ``/var/pcp/lib:/usr/pcp/lib'',   (or   ``/var/lib/pcp/lib''   on
	      Linux, depending on the value of	the  $PCP_VAR_DIR  environment
	      variable).

       PMCD_PORT
	      The  TPC/IP  port(s)  used  by  pmcd(1) to create the socket for
	      incoming connections and requests,  was  historically  4321  and
	      more  recently the officially registered port 44321; in the cur‐
	      rent release, both port numbers are used by default as a transi‐
	      tional   arrangement.    This  may  be  over-ridden  by  setting
	      PMCD_PORT to a different port number, or a comma-separated  list
	      of  port	numbers.   If  a non-default port is used when pmcd is
	      started, then every monitoring application  connecting  to  that
	      pmcd  must  also	have PMCD_PORT set in their environment before
	      attempting a connection.

       The following environment variables are relevant	 to  installations  in
       which pmlogger(1), the PCP archive logger, is used.

       PMLOGGER_PORT
	      The environment variable PMLOGGER_PORT may be used to change the
	      base TCP/IP port number used by pmlogger(1) to create the socket
	      to  which	 pmlc(1)  instances will try and connect.  The default
	      base port number is 4330.	 When used,  PMLOGGER_PORT  should  be
	      set in the environment before pmlogger is executed.

       PMLOGGER_REQUEST_TIMEOUT
	      When  pmlc(1)  connects to pmlogger(1), there is a remote possi‐
	      bility of pmlc "hanging" on a request for information as a  con‐
	      sequence	of  a  failure of the network or pmlogger.  By setting
	      the environment variable PMLOGGER_REQUEST_TIMEOUT to a number of
	      seconds,	requests to pmlogger will timeout after this number of
	      seconds.	The default behavior is to be willing to wait  forever
	      for  a  response	from  each  request to a pmlogger.  When used,
	      PMLOGGER_REQUEST_TIMEOUT should be set in the environment before
	      pmlc is executed.

       If  you	have the PCP product installed, then the following environment
       variables  are  relevant	 to  the  Performance  Metrics	Domain	Agents
       (PMDAs).

       PMDA_LOCAL_PROC
	      Use this variable has been deprecated and it is now ignored.  If
	      the ``proc'' PMDA is configured as a DSO for use with pmcd(1) on
	      the  local  host then all of the ``proc'' metrics will be avail‐
	      able to applications using a PM_CONTEXT_LOCAL context.

	      The previous behaviour was that if this variable was set, then a
	      context  established with the type of PM_CONTEXT_LOCAL will have
	      access to the ``proc''  PMDA  to	retrieve  performance  metrics
	      about individual processes.

       PMDA_LOCAL_SAMPLE
	      Use this variable has been deprecated and it is now ignored.  If
	      the ``sample'' PMDA is configured as a DSO for use with  pmcd(1)
	      on  the  local  host  then all of the ``sample'' metrics will be
	      available to applications using a PM_CONTEXT_LOCAL context.

	      The previous behaviour was that if this variable was set, then a
	      context  established with the type of PM_CONTEXT_LOCAL will have
	      access to the ``sample'' PMDA if this  optional  PMDA  has  been
	      installed locally.

       PMIECONF_PATH
	      If set, pmieconf(1) will form its pmieconf(5) specification (set
	      of parameterized pmie(1) rules) using all valid  pmieconf	 files
	      found  below  each  subdirectory in this colon-separated list of
	      subdirectories.  If not set, the	default	 is  $PCP_VAR_DIR/con‐
	      fig/pmieconf.

FILES
       /etc/pcp.conf
		 Configuration	file  for  the	PCP  runtime  environment, see
		 pcp.conf(5).
       /etc/pki/nssdb
		 Optionally contains a Network Security Services database with
		 a  "PCP  Collector" certificate providing trusted identifica‐
		 tion for the collector host.
       $HOME/.pcp
		 User-specific directories containing configuration files  for
		 customisation	 of   the   various  monitor  tools,  such  as
		 pmchart(1).
       $HOME/.pki/nssdb
		 A shared Network Security Services (NSS)  database  directory
		 containing  per-user  certificates  identifying  known	 valid
		 remote pmcd collector hosts.  The NSS certutil tool is one of
		 several that can be used to maintain this database.
       $PCP_RC_DIR/pcp
		 Script for starting and stopping pmcd(1).
       $PCP_PMCDCONF_PATH
		 Control file for pmcd(1).
       $PCP_PMCDOPTIONS_PATH
		 Command  line	options	 passed	 to pmcd(1) when it is started
		 from $PCP_RC_DIR/pcp.	All  the  command  line	 option	 lines
		 should start with a hyphen as the first character.  This file
		 can also contain environment variable settings	 of  the  form
		 "VARIABLE=value".
       $PCP_BINADM_DIR
		 Location  of PCP utilities for collecting and maintaining PCP
		 archives, PMDA help text, PMNS files etc.
       $PCP_PMDAS_DIR
		 Parent directory of the installation  directory  for  Dynamic
		 Shared Object (DSO) PMDAs.
       $PCP_RUN_DIR/pmcd.pid
		 If  pmcd is running, this file contains an ascii decimal rep‐
		 resentation of its process ID.
       $PCP_LOG_DIR/pmcd
		 Default location of log files for pmcd(1), current  directory
		 for  running  PMDAs.	Archives  generated by pmlogger(1) are
		 generally below $PCP_LOG_DIR/pmlogger.
       $PCP_LOG_DIR/pmcd/pmcd.log
		 Diagnostic and status log for	the  current  running  pmcd(1)
		 process.   The	 first	place  to look when there are problems
		 associated with pmcd.
       $PCP_LOG_DIR/pmcd/pmcd.log.prev
		 Diagnostic and status log for the previous pmcd(1) instance.
       $PCP_LOG_DIR/NOTICES
		 Log  of  pmcd(1)  and	PMDA  starts,  stops,  additions   and
		 removals.
       $PCP_VAR_DIR/config
		 Contains  directories	of configuration files for several PCP
		 tools.
       $PCP_SYSCONF_DIR/pmcd/rc.local
		 Local script for controlling PCP boot, shutdown  and  restart
		 actions.
       $PCP_VAR_DIR/pmns
		 Directory  containing the set of PMNS files for all installed
		 PMDAs.
       $PCP_VAR_DIR/pmns/root
		 The ASCII pmns(5) exported by pmcd(1) by default.  This  PMNS
		 is  be	 the  super  set  of all other PMNS files installed in
		 $PCP_VAR_DIR/pmns.
       In addition, if the PCP product is installed the	 following  files  and
       directories are relevant.
       $PCP_LOG_DIR/NOTICES
	      In addition to the pmcd(1) and PMDA activity, may be used to log
	      alarms and notices from pmie(1) via pmpost(1).
       $PCP_PMLOGGERCONTROL_PATH
	      Control	file   for   pmlogger(1)   instances   launched	  from
	      $PCP_RC_DIR/pcp  and/or  managed by pmlogger_check(1) and pmlog‐
	      ger_daily(1) as part of a production PCP archive collection set‐
	      up.

PCP ENVIRONMENT
       Environment variables with the prefix PCP_ are used to parameterize the
       file and directory names used by PCP.  On each installation,  the  file
       /etc/pcp.conf  contains	the  local  values  for	 these variables.  The
       $PCP_CONF variable may be used to specify an alternative	 configuration
       file, as described in pcp.conf(5).

SEE ALSO
       pmcd(1),	  pmie(1),  pmie_daily(1),  pminfo(1),	pmlc(1),  pmlogger(1),
       pmlogger_daily(1),   pmstat(1),	  pmval(1),    pcp(1),	  pcp.conf(5),
       pcp.env(5), and pmns(5).

       If  the	PCP  GUI  package is installed, then the following entries are
       also relevant:
       pmchart(1), pmtime(1), and pmdumptext(1).

       If the secure sockets extensions have been enabled, then the  following
       references are also relevant:
       http://oss.sgi.com/projects/pcp/pcp-gui.git/man/html/index.html
       http://www.mozilla.org/projects/security/pki/nss/#documentation
       http://www.mozilla.org/projects/security/pki/nss/tools/certutil.html

       Also refer to the books Performance Co-Pilot User's and Administrator's
       Guide and Performance Co-Pilot Programmer's Guide which can be found at
       http://techpubs.sgi.com.

Performance Co-Pilot		      PCP			   PCPINTRO(1)
[top]

List of man pages available for Oracle

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net