MPE_Close_graphics(4)		      MPE		 MPE_Close_graphics(4)

NAME
       MPE_Close_graphics -  Closes an X11 graphics device

SYNOPSIS
       #include "mpe.h"
       int MPE_Close_graphics( handle )
       MPE_XGraph *handle;

INPUT PARAMETER
       handle - MPE graphics handle.

RETURN VALUES
       MPE_ERR_BAD_ARGS
	      - 'handle' parameter is bad
       MPE_SUCCESS
	      - success

NOTES FOR FORTRAN INTERFACE
       The  Fortran interface to this routine is different from its C counter‐
       part and it has an additional argument, ierr, at the end of  the	 argu‐
       ment  list,  i.e.  the  returned	 function  value (the error code) in C
       interface is returned as the additional argument in Fortran  interface.
       The Fortran interface is invoked with the CALL statement.

       All  MPI	 and  MPE  objects, MPI_Comm, MPE_XGraph and MPE_Color, are of
       type INTEGER in Fortran.

LOCATION
				   3/24/2011		 MPE_Close_graphics(4)