codasrv(8)codasrv(8)NAMEcodasrv - CFS file server
SYNOPSIScodasrv [-d (debug level)] [-rpcdebug rpc2debuglevel] [-p (number of
processes)]
[-l (large vnodes)] [-s (small vnodes)] [-k (stack size)]
[-w (wait interval)] [-r (RPC retry count)]
[-o (RPC timeout)] [-c (check interval)]
[-t (RPC trace buffers)] [-forcesalvage]
[-quicksalvage] [-rvm logdevice datadevice length] [-nores]
[-trunc percent] [-nocmp] [-nopy] [-nodumpvm] [-nosalvageonshutdown]
[-mondhost hostname] [-mondportal port] [-debarrenize] [-optstore]
[-rvmopt] [-newchecklevel checklevel]
DESCRIPTIONcodasrv is the CFS vice file server. It services requests from client
machines venus processes and maintains the file system.
Srvs command line options are:
-d <debug level>
Sets the internal debugging level to <debug level>. This con‐
trols the amount of debugging output codasrv will generate.
-p <number of processes>
Sets the number of light weight processes that will be used to
handle concurrent requests.
-l <large vnodes>
number of large vnodes in lru cache
-s <small vnodes>
number of small vnodes in lru cache
-k <stack size>
stack size of LWP threads in Kbytes
-w <wait interval>
interval for CallBackCheckLWP to see which clients are alive
-r <RPC retry count>
number of times a call is retried before reporting death
-o <RPC timeout>
default timeout for all rpcs
-c <check interval>
The interval at which shutdown is checked
-t <RPC trace buffers>
number of entries in the rpc trace buffer
-forcesalvage
force a full salvage on all volumes
-quicksalvage
salvage only the headers of the volumes - currently it always
does a full
-rvm logdevice datadevice length
The -rvm switch allows you to specify the locaction of the log
device, data device, and length of the recoverable segment used
by the server. This parameter is not optional.
-nores Turn off resolution on the servers
-trunc percent
Specify how full the log can get before it is truncated.
Default is 50%
-nocmp Directory replica contents will not be checked for equality at
end of resolution
-nopy Suppress polling and yielding by threads that run for a long
period
-nodumpvm
Do not dump in-memory copy of recoverable segment before shut‐
down
-nosalvageonshutdown
Do not salvage volumes on shutdown
-mondhost hostname
Host where mond database is stored
-mondportal port
Port to use when contacting the mond host.
-debarrenize
Create an inode for a vnode if the inode cannot be found by the
salvager
-opstore
Optimized Stores - return to the client before sftp completes
-rvmopt
Turn on inter/intra transaction rvm optimizations
-newchecklevel checklevel
Set the level of checking done by new plumber.
FILES
/vice/srv/SrvErr
/vice/srv/SrvLog*
SEE ALSO
startserver (8)
AUTHOR
Joshua Raiff, 1993, Created man page
codasrv(8)